P110 Language
Selection:
0
German
1
English
This parameter specifies the language used by the diagnostic software.
Independently of the setting of P110 (language) and P100 (access code), the language can
also be set with the SIMOCRANE CeCOMM diagnostic program (Windows Options/Language
menu function).
Default: 1
Access code: 3
Display: Always
P111 Smoothing factor for actual velocities
This parameter can be used to smooth the determined actual velocity. The factor applies to the
actual velocities of all axes. Smaller values results in more smoothing; the maximum value 1.0
results in no smoothing.
Default: 0
min: 0
max: 1
Access code: 2
Display: Always
P112 Reduction factor for lowering velocity (SAM)
Percentage factor for reducing the set velocity when lowering. The parameter is only operative
if the trolley and hoist are moved simultaneously and the actual position of the spreader is below
the interpolation point straight line. The trolley position must also be located in the set operative
range P113.
Default: 20 [%]
min: 5 [%]
max: 100 [%]
Access code: 3
Display: Always
P113 Operative range of P112 (SAM)
This parameter influences the operative range of P112. The remaining distance of the trolley
from the start of lowering to the target is multiplied by P113 to obtain the operative range. If the
trolley position is within the operative range, reduction factor P112 is active.
Default: 50 [%]
min: 0 [%]
max: 100 [%]
Access code: 3
Display: Always
Parameters
11.5 General
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
411