Bit no.
Name
Meaning
14
move_zero
Activate the TLS mode "go to zero positions"
15
as_on
Skew-damping On/Off
Note
Out, in, up, down refer to the Figure 7-4 Directions of movement (Page 240).
Table 3-14
Control bits in control word 2
Bit no.
Name
Meaning
0
a_in_comm
Cylinder jogging: Retract cylinder A
1
b_in_comm
Cylinder jogging: Retract cylinder B
2
c_in_comm
Cylinder jogging: Retract cylinder C
3
d_in_comm
Cylinder jogging: Retract cylinder D
4
a_out_comm
Cylinder jogging: Extend cylinder A
5
b_out_comm
Cylinder jogging: Extend cylinder B
6
c_out_comm
Cylinder jogging: Extend cylinder C
7
d_out_comm
Cylinder jogging: Extend cylinder D
8
skewpos_ext
Set position for the skew drive is specified from an external source
9
SkA_in_comm
Move skew axis in
10
SkA_out_comm
Move skew axis out
11
move_SkA
Activate position control of electric skew drive
12
reset_mdl
Reset internal oscillation model
13
hold_trim_list
Hold the trim and list positions
14
-
Reserved
15
-
Reserved
Table 3-15
Status bits in status word 1
Bit no.
Name
Meaning
0
-
-
1
motion_terminated_SkA
Motion terminated,
skew drive
2
zero
Zero position reached
3
motion_terminated
Motion terminated,
cylinder
4
skew_removed
Skew oscillation eliminated
5
-
6
-
7
-
8
a_out
Extend cylinder A
9
b_out
Extend cylinder B
Overview of the software
3.3 Sway control function blocks
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
51