Figure 5-12
NetPro overview with camera via PROFINET
5.5.2
General information
Open the (SCOUT) application project of the Basic Technology [Ref. 2] (user project) and the
supplied SCOUT application project of the AddOn technology (application project). Later, once
PROFINET has been configured, you can copy the programs from one project into the other
project.
Communication between the higher-level SIMATIC S7 control and the drive-related control
SIMOTION D4x 5-2 DP/PN is established via PROFINET PN. The SINAMICS Control Unit is
integrated in the drive-based SIMOTION D [Ref. 5] and [Ref. 6].
Configuration
5.5 PROFINET configuration
SC integrated STS, GSU
120
Operating Instructions, 07/2019, A5E48271265B AA