Table 4-29
ZSW1_TLS_PLC
Bit
Signal name
Remark
0
-
-
1
motion_terminated_ska
0: Conditions for stopping the skew drive are not fulfilled
1: Motion terminated, skew drive
2
zero
0: Conditions for zero position are not fulfilled
1: Zero position reached
3
motion_terminated
0: Conditions for stopping the cylinders are not fulfilled
1: Cylinder motion terminated
4
skew_removed
0: Conditions for removing skew are not fulfilled
1: Skew oscillation eliminated
Amplitude of the oscillation is less than P301.
Note:
Noisy camera signals psi_cam also cause a certain level of noise in the model
angle psi_model. This can result in flickering of the status bit skew_removed. In
this case, the bit should be evaluated via an additional timer in the higher-level
control system.
5
-
Reserved
6
-
Reserved
7
-
Reserved
8
a_out
0: Cylinder A is not extended
1: Cylinder A is extended
9
b_out
0: Cylinder B is not extended
1: Cylinder B is extended
10
c_out
0: Cylinder C is not extended
1: Cylinder C is extended
11
d_out
0: Cylinder D is not extended
1: Cylinder D is extended
12
a_in
0: Cylinder A is not retracted
1: Cylinder A is retracted
13
b_in
0: Cylinder B is not retracted
1: Cylinder B is retracted
14
c_in
0: Cylinder C is not retracted
1: Cylinder C is retracted
15
d_in
0: Cylinder D is not retracted
1: Cylinder D is retracted
Communication interface to SIMATIC S7
4.2 SIMOTION D for AddOn → SIMATIC S7
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
105