P254 Set velocity cylinder
Maximum set velocity in all TLS operating modes
Default: 4 [mm/s]
min: 0 [mm/s]
max: 100000 [mm/s]
Access code: 0
P255 Set acceleration cylinder
Maximum set acceleration in all TLS operating modes
Default: 40 [mm/s
2
]
min: 0 [mm/s
2
]
max: 100000 [mm/s
2
]
Access code: 0
P256 Maximum trim position
Maximum trim position for "TLS jogging" and "TLS positioning"
Default: 150 [mm]
min: 0 [mm]
max: 100000 [mm]
Access code: 0
P257 Maximum list position
Maximum list position for "TLS jogging" and "TLS positioning"
Default: 150 [mm]
min: 0 [mm]
max: 100000 [mm]
Access code: 0
P258 Maximum skew position
Maximum skew position for "TLS jogging" and "TLS positioning"
Default: 150 [mm]
min: 0 [mm]
max: 100000 [mm]
Access code: 0
P259 Maximum h component
Maximum h component for "TLS jogging" and "TLS positioning"
The h component represents a vertical displacement of the container.
Default: 50 [mm]
min: 0 [mm]
max: 100000 [mm]
Access code: 0
Parameters
11.9 TLS
SC integrated STS, GSU
Operating Instructions, 07/2019, A5E48271265B AA
423