Electrical connection
8.3 System integration
1FW68 radial segment motors
Configuration Manual, 08/2021, A5E51132930B AA
165
Components
•
1 CU 320-2 Control Unit
•
1 Active Interface Module AIM to dampen line oscillations
•
1 Active Line Module ALM as infeed and rectifier
•
5 Motor Modules as inverters
•
9 circuit breakers
•
9 stator segments subdivided into 5 groups
–
Group 1 (master drive):
2 stator segments connected in parallel to one Motor Module; encoder evaluation
only via group 1
–
Group 2 to group 4 (slave drives):
2 stator segments connected in parallel to one Motor Module, groups are
identically configured
–
Group 5 (slave drive):
1 stator segment separately connected to one Motor Module
•
Cables
For each stator segment with a current demand higher than 66 A:
–
3 single-core cables for the power connection
–
1 signal cable for connecting the temperature sensors
–
1 single-core cable for the protective conductor connection PE
For each stator segment with a current demand up to 66 A:
–
1 combined cable for the power connection, connection of the temperature
sensors, and protective conductor connection PE
•
5 TM120 Terminal Modules for
–
Temperature sensor evaluation
–
Protective separation
•
1 SMC20 Sensor Module Cabinet-Mounted to connect the encoder and to evaluate
the encoder signal
•
Internal encoder signal splitting with TEC SERVCOUP
Note
Protective conductor terminal PE
In the following connection diagrams, the cables for the protective conductor connection
PE are shown only on the Active Interface Module AIM for reasons of clarity.