Protection against humidity
If a dry storage area is not available, then take the following precautions:
•
Wrap the motor in humidity-absorbent material. Then wrap it in foil so that it is air
tight.
•
Include several bags of desiccant in the sealed packaging. Check the desiccant and
replace it as required.
•
Place a humidity meter in the sealed packaging to indicate the level of air humidity
inside it.
•
Inspect the motor on a regular basis.
Protecting the cooling system for motors with integrated cooling
Before you store the motor after use, perform the following actions:
•
Empty the cooling channels.
•
Blow out the cooling ducts with dry, compressed air so that the cooling ducts are
completely empty.
•
Seal the connections of the cooling system.