Mechanical properties
3.1 Cooling
1FW68 radial segment motors
52
Configuration Manual, 08/2021, A5E51132930B AA
Materials used in the cooling circuits of stator segments
The stator segment cooling circuits contain the following materials (without the
connecting component materials):
•
1.4301/1.4305 /1.4310
•
FKM 70
•
CW024A according to EN 1057
•
70G30HSLR BK 099
NOTICE
Corrosion as a result of unsuitable materials used to connect the cooler
Corrosion damage can occur if you use unsuitable materials to connect to the cooler.
•
We recommend that you use brass or stainless steel fittings when connecting the
cooler.
Calculating the thermal power that can be dissipated by the cooler
Average density of the coolant:
ρ
in kg/m
3
Average specific heat capacity of the coolant:
c
p
in J/(kg K)
Temperature deviation vis-à-vis the intake temperature:
Δ
T in K
Volume flow:
in m
3
/s
Coolant intake temperature
NOTICE
Corrosion in the machine
Condensation can lead to corrosion in the machine.
•
Select the intake temperatures so that no condensation forms on the surface of the
motor. Condensation does not form if the intake temperature T
VORL
is higher than the
ambient temperature or corresponds to the ambient temperature.