Electrical connection
8.3 System integration
1FW68 radial segment motors
Configuration Manual, 08/2021, A5E51132930B AA
159
8.3.9
Signal connection
No direct connection of the temperature monitoring circuits
WARNING
Risk of electric shock when incorrectly connecting the temperature monitoring
circuit
In the case of a fault, circuits Temp-S and Temp-F do not provide safe electrical
separation with respect to the power components.
•
Use the TM120 to connect the Temp-S and Temp-F temperature monitoring circuits.
You therefore comply with the directives for safe electrical separation according to
EN 61800-5-1 (previously safe electrical separation according to EN 50178).
Correctly connecting temperature sensors
NOTICE
Motor destroyed as a result of overtemperature
The motor can be destroyed as a result of overtemperature if you do not correctly
connect the temperature sensors.
•
When connecting temperature sensor cables with open conductor ends, pay
attention to the correct assignment of conductor colors.
Table 8- 10 Core assignment of the temperature sensor cables for PTC and Pt1000 for cable
6FX7002-2SL20-...
Conductor color
PIN
Interface
White
1
1R2: Pt1000
Brown
2
1R1: Pt1000
Green
3
1TP1: PTC
Yellow
4
1TP2: PTC
Gray
5
-
Pink
6
-
Green/yellow
PE