Electrical connection
8.3 System integration
1FW68 radial segment motors
Configuration Manual, 08/2021, A5E51132930B AA
157
8.3.8
Power connection
Note
Protective conductor PE
There are four ways of connecting the protective conductor PE for stator segments with
a current higher than 66 A.
•
Connect the protective conductor (PE) to one connection point.
•
Operate the stator segments only with connected protective conductor PE.
Minimum protective conductor cross-sections
The minimum cross-sections for protective conductors are defined in EN 60034-1 as
follows:
Cross-section S of the current-carrying
conductor
Minimum protective conductor cross-section
S
≤
25 mm
2
S
25 mm
2
< S
≤
50 mm
2
25 mm
2
S > 50 mm
2
½ * S
Connection assignment
Table 8- 9 Power connection for a stator segment
Motor Module
Stator segment
U2
U
V2
V
W2
W
Pin assignment, plug connector (connector size 1.5) of the combination cable
for stator segment 1FW68 up to 66 A
PIN
Name
U
Phase U
V
Phase V
W
Phase W
PE
1
1TP1: PTC
2
1TP2: PTC
(+)
1R1: Pt1000
(-)
1R2: Pt1000
Summary of Contents for SIMOTICS T-1FW68