Configuring
5.1 Configuring workflow
1FW68 radial segment motors
94
Configuration Manual, 08/2021, A5E51132930B AA
•
Field weakening operation
If an operating point in range C is required, then the motor must be operated in the
field weakening range (see the following diagram).
Advantage: Significantly higher speeds are possible.
Disadvantage: The torques available are very low.
A lower current is required, refer to the description for field weakening operation in
Chapter "Technical data and characteristics"
Figure 5-9 Requirement: Field weakening
5.1.10
Checking the moments of inertia
Once a suitable motor has been selected, the moment of inertia of the rotating mass on
the axis has been determined. This value can be used to check the assumptions made
regarding the duty cycle.
Recalculating the duty cycle
If the moment of inertia initially assumed deviates significantly from the actual moment
of inertia, the duty cycle may have to be recalculated.