Electrical connection
8.3 System integration
1FW68 radial segment motors
Configuration Manual, 08/2021, A5E51132930B AA
169
The phase positions EMF phase U
–
EMF phase V
–
EMF phase W of the individual
stator segments must match one another.
•
EMF phase U stator segment 1 with EMF phase U stator segment n
•
EMF phase V stator segment 1 with EMF phase V stator segment n
•
EMF phase W stator segment 1 with EMF phase W stator segment n
The EMF phase U stator segment n may lead or lag EMF phase U stator segment 1 by a
maximum of 10
°
electrical.
The deviation within a particular phase position may be a maximum of 10
°
.
Figure 8-9 Lagging EMF phase U stator segment 1