Configuring
5.2 Mounting
1FW68 radial segment motors
122
Configuration Manual, 08/2021, A5E51132930B AA
5.
Tighten the screws of the two outer T-sliding blocks.
6.
Proceed in a similar way for all of the other stator segments to be mounted.
❒
5.2.5
Checking the work carried out
Checking the mounting work
Before moving the rotor, remove all tools and objects from the swivel range and air gap.
After mounting has been completed, check that the rotor can freely rotate. Note that with
short-circuited motor phases, the rotor is difficult to turn - even if no mechanical
resistance is otherwise present.
WARNING
Risk of electric shock
A voltage is induced in the stator when the rotor is rotated. There is risk of an electric
shock if you touch the terminals, the open cable ends or the connector contacts.
•
Correctly connect the motor power cables.
Alternatively:
Insulate the connector contacts or terminals and conductors of open cable ends
before you rotate the rotor.