Electrical connection
8.3 System integration
1FW68 radial segment motors
160
Configuration Manual, 08/2021, A5E51132930B AA
Example of a connection for the temperature monitoring circuits
The connection for the temperature sensors of a segment motor with 9 stator segments
is subsequently shown as an example. Stator segments 1 to 8 are subdivided into groups
Gr1 to Gr4. The 9th stator segment is group Gr5. Every temperature fault of a stator
segment can be clearly localized, see system integration diagrams in Chapter "Coupled
stator segments".
Electrical separation SET for the temperature sensors is implemented using the TM120
Terminal Module.
•
Connect the open connector ends of the signal cables to the TM120.
•
Connect the shield to the appropriate TM120 terminal.
•
Use strain relief.
Table 8- 11 TM120 connection assignment
Group 1 to group 4
Group 5
TM120
Temperature sensor
TM120
Temperature sensor
X521.1
PTC
X521.1
PTC
X521.2
PTC
X521.2
PTC
X521.3
Pt1000
X521.3
Pt1000
X521.4
Pt1000
X521.4
Pt1000
X521.5
PTC
X521.6
PTC
X521.7
Pt1000
X521.8
Pt1000