51
4. Parameter description
Parameter
Time
Output
frequency
(
Hz
)
P.13
Startup signal input
4.9
Load pattern selection (P.14, P.98, P.99, P.162~P.169)
P.14 “Load pattern selection”
P.98 “Middle frequency 1”
P.99 “Voltage output at middle
frequency 1”
P.162 “Middle frequency 2”
P.163 “Voltage output at middle
frequency 2”
P.164 “Middle frequency 3”
P.165 “Voltage output at middle
frequency 3”
P.166 “Middle frequency 4”
P.167 “Voltage output at middle
frequency 4”
P.168 “Middle frequency 5”
P.169 “Voltage output at middle
frequency 5”
Related parameters
P. 46
“
Second torque boost
”
P.80~P.84, P. 86
“
Multi - function terminals selection
”
P. 0
“
Torque boost
”
Parameter
Factory setting
Setting range
Remarks
14
0
0~13
When P.14=5~13, it provides 9 kinds
of different VF curve.
98
3Hz
0~400Hz (Note 3)
---
99
10%
0~100%
---
162
9999
0~400Hz, 9999 (Note 3)
---
163
0%
0~100%
---
164
9999
0~400Hz, 9999 (Note 3)
---
165
0%
0~100%
---
166
9999
0~400Hz, 9999 (Note 3)
---
167
0%
0~100%
---
168
9999
0~400Hz, 9999 (Note 3)
---
169
0%
0~100%
---