137
Appendix 1 Parameter list
Parameter list
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User setting
value
Reference
page
P.249
Automatic switchover
frequency from inverter to
bypass operation
0~60Hz,9999
0.01Hz
9999
P114
P.250
Automatic switchover
frequency range from bypass to
inverter operation
0~10Hz,9999
0.01Hz
9999
P114
P.288
Alarm history number
0~12
1
0
P117
P.289
Alarm code
---
---
0
P117
P.290
The
latest alarm status
selection
0~5
1
0
P117
P.291
The latest alarm status
---
---
0
P117
P.292
Accumulative motor operation
time (min)
0~1439min
1min
0min
P118
P.293
Accumulative motor operation
time (day)
0~9999day
1day
0day
P118
P.294
Password input
0~65535
1
0
P119
P.295
Password set
0~65535
1
0
P119
P.300 Motor control mode selection
0~3
1
0
P119
P.301
Motor parameter auto
measurement function selection
0~3
1
0
P119
P.302 Motor rated power
0~160
0.01
0
P121
P.303 Motor poles
0~8
1
4
P121
P.304 Motor rated voltage
0~440V
1 V
220/440V
P121
P.305 Motoe rated frequency
0~400Hz
0.01Hz
50Hz/60Hz
(
Note 2
)
P121
P.306 Motoe rated current
0~500A
0.01 A
Determined by
horsepower
P121
P.307 Motoe rated speed
0~65535
r/min
1 r/min
1410/1710 r/min
(
Note 2
)
P121
P.308 No load excitation current
0~500A
0.01 A
Determined by
horsepower
P121
P.309 Stator resistance
0~65535
0.01
Determined by
horsepower
P121
P.310 Rotor resistance
0~65535
0.01
Determined by
horsepower
P121
P.311 Leakage inductance
0~65535
0.1
Determined by
horsepower
P121
P.312 Mutual inductance resistance
0~65535
0.1
Determined by
horsepower
P121