4. Parameter description
Parameter
4.36
Multi-function terminals function selection (P.80~P.84, P.86)
P.80~P.84, P.86 “Multi-function terminals function selection”
Para-
meter
Termi
nal
Factory
setting
Setting
range
Value
Function
name
Function description
Remarks
80
M0
2
0~39
0
STF
In
‘external
mode’,
‘combined mode 1’, or
‘combined mode 3’,
when STF is ‘on’, the
inverter runs forwards.
In programmed
operation mode,
it is used as start
signal terminal.
1
STR
In
‘external
mode’,
‘combined mode 1’, or
‘combined mode 3’,
when STF is ‘on’, the
inverter runs reverse.
In programmed
operation mode,
it is used as
pause signal
terminal.
2
RL
Multi-speed
Please refer to
P.4~P.6
3
RM
Multi-speed
4
RH
Multi-speed
Please refer to
P.4~P.6
81
M1
3
0~39
5
AU
In
‘external
mode’,
‘combined mode 2’or
‘combined mode 4’,
when AU is ‘on’, the
inverter
target
frequency is set by the
signal
input across
terminal 4-5.
Please refer to
P.39
6
OH
(Note 3)
7
MRS
When MRS is ‘turned
on’,
the output
terminates.
8
RT
When RT is ‘on’, the
characteristics are the
same as the second
function.
Please refer to
P.44
9
EXJ
(
External
JOG
)
In
‘external mode’,
when EXJ is ‘on’
,
the
target frequency is set
by P.15, the
acceleration/
deceleration time is set
by P.16 (Note 4).