124
4. Parameter description
Parameter
4.69
INV Reset (P.997)
P.997 “INV Reset”
● Once P.997 is read out (after read out, the screen will display
) and rewritten in, the
inverter is reset. Once the inverter is reset, the values of the ‘electronic thermal relay’ and the
‘IGBT module thermal relay’ will be set to zero.
4.70
Parameter initialization (P.998, P.999)
P.998 “Parameter total- initialization”
P.999 “Parameter partial- initialization”
● Once P.998 is read out (after read out, the screen will display
) and rewritten in, all
parameters except P.21, P.125, P.187, P.188, P.189, P.292, P.293 will be restored to the default
values.
● Once P.999 is read out (after read out, the screen will display
) and rewritten in, all
parameters except P.21, P.125, P.187, P.188, P.189, P.192, P.194~P.197, P.292, P.293, P.300~P.312
will be restored to the default values.
● Please make sure that do not carry out any other operations before the screen displays
,
which indicates that the corresponding parameters has been restored to the default values.