100
4. Parameter description
Parameter
frequency
RL
ON
ON
ON
ON
ON
ON
ON
ON
……
P.131
P.132
P.133
P.134
P.135
P.131
P.132
0
Note: 1. The inverter will run the most 8 section, the frequency is determined by P.131~P.138
2. When the frequency is setting, if any section is 0,
the inverter will run
standby in this section.It means
that in thid mode the value of P.131 is not 0. Like the figur
e
above, no matter how value of P.137 and
P.138, when the press the switch sixth, the inverter will stop.
3. Manually operation circle mode has a single rotation direction. It has nothing to do with P.121 and STF or
STR signal.
4. If P.187=1, P.131~P.138 are in the range of 0~1000Hz.
4.40 Operation panel frequency monitoring selection function (P.110)
P.110 “Operation panel frequency monitoring selection”
Parameter
Factory
setting
Setting
range
Remarks
110
0
0, 1, 2
0
When the inverter starts, the operation panel enters the
monitoring mode automatically, and the screen displays
the output frequency.
1
When the inverter starts, the screen of the operation
panel displays the target frequency.
2
When the inverter starts, the operation panel enters the
monitoring mode automatically, and the screen displays
the output frequency steady.
4.41
Expansion board function (P.125~P.130)
P.125 “Expansion board type”
P.126 “I/0 expansion board input terminal M3 function selection”
P.127 “I/0 expansion board input terminal M4 function selection”
P.128 “I/0 expansion board input terminal M5 function selection”
P.129 “I/0 expansion board output relay1 function selection”
P.130 “I/0 expansion board output relay2 function selection”