128
Appendix 1 Parameter list
Parameter list
Parameter
number
Name
Setting range
Minimum
setting unit
Default value
User setting
value
Reference
page
P.0
Torque boost
0~30%
0.1%
(Note 1)
P43
P.1
Maximum frequency
0~120Hz
0.01Hz
120Hz
P44
P.2
Minimum frequency
0~120Hz
0.01Hz
0Hz
P44
P.3
Base frequency
0~400Hz
0.01Hz
50Hz/60Hz
(Note 2)
P44
P.4
Speed 1 (high speed)
0~400Hz
0.01Hz
60Hz
P46
P.5
Speed 2 (middle speed)
0~400Hz
0.01Hz
30Hz
P46
P.6
Speed 3 (low speed)
0~400Hz
0.01Hz
10Hz
P46
P.7
Acceleration time
0~360.00s/
0~3600.0s
0.01s/0.1s
5s
P47
P.8
Deceleration time
0~360.00s/
0~3600.0s
0.1s/0.01s
5s
P47
P.9
Electronic thermal relay
capacity
0~500A
0.01A
Motors rated current
(Note 1)
P49
P.10
DC injection brake
operation frequency
0~120Hz
0.01Hz
3Hz
P49
P.11
DC injection brake
operation time
0~60
s
0.1
s
0.5
s
P49
P.12 DC injection brake voltage
0~30%
0.1%
4%
P49
P.13 Starting frequency
0~60Hz
0.01Hz
0.5Hz
P50
P.14 Load pattern selection
0~13
1
0
P51
P.15 JOG frequency
0~400Hz
0.01Hz
5Hz
P54
P.16
JOG acceleration /
deceleration time
0~360.00s/
0~3600.0s
0.1s/0.01s
0.5s
P54
P.17
Input signal across terminal
4-5 selection
0
、
1
1
0
P54
P.18
High-speed maximum
frequency
120~400Hz
0.01Hz
120Hz
P44
P.19 Base frequency voltage
0~1000V, 9999
0.1V
9999
P44
P.20
Acceleration/deceleration
reference frequency
1~400Hz
0.01Hz
50Hz/60Hz
(Note 2)
P47
P.21
Acceleration/deceleration
time increments
0,1
1
0
P47
P.22
Stall prevention operation
level
0~400%
0.1%
200%
P55
P.23
Offset coefficient for Stall
prevention operation level
at double speed
0~200%, 9999
0.1%
9999
P55
P.24 Speed 4
0~400Hz, 9999
0.01Hz
9999
P46