147
Appendix 5 Optional equipment
Optional equipment
(7). DeviceNet communication expansion board (SE2-DN01)
1). SE2-DN01 meets ODVA DeviceNet standards.
2). SE2-DN01 as a slave for DeviceNet network, support for 125k, 250k, 500k baud rate of
communication
3). SE2-DN01 using a common terminal form to connect DeviceNet network, addresses is from
0 to 63.
4). Connect SE2-DN01, please use the standard DeviceNet specific cable.
5). The power of SE2-DN01 is supplied by the 24V power supply from DeviceNet network.
Terminal type
Terminal
name
Function
name
Remarks and function description
DeviceNet
communication
terminal
V+
V+
Isolated 24V power supply
CAN+
CAN_H
CAN_H signal
SHIELD
SHIELD
Network cable shield
CAN-
CAN_L
CAN_L signal
V-
V-
Isolated ground
---
Empty
---
NS LED: Instructed SE2-DN01 and the DeveceNet network connection status.
MS LED: Instructions SE2 - DN01 internal modules working condition.
SP LED: Instructed the inverter and SE2-DN01 Working condition.
Address switch 1~6: Set the communication address of SE2-DN01 in DeviceNet network.
Baud rate setting switch 7~8: Set the communication rate of SE2-DN01.
Note: 1. 00 representative of 125k, 01 representative of 250k, 10 representative of 500k, 11 representative
automatically set baud rate.
2. The shihlin inverter can automatically identify the SE2-DN01 communications expansion board, and adjust
the corresponding parameters of its own with the SE2-DN01 to make a successful connection, the user in
the course of communication do not modify the drive parameters, so as not to affect the SE2-DN01 normal
work