background image

 

W

W

S

S

-

-

1

1

2

2

5

User Manual 

Version 1.0 

Infosystem Technology Corporation, Ltd. 

2 RS232 Ports to Ethernet Converter with Multi-Sockets 

Summary of Contents for WS-125

Page 1: ...W W S S 1 1 2 2 5 5 User Manual Version 1 0 Infosystem Technology Corporation Ltd 2 RS232 Ports to Ethernet Converter with Multi Sockets ...

Page 2: ...Applications 5 3 Exterior 6 A Front View 6 B Global View 7 C Front Panel 8 D Dimension 8 4 Specification 9 A Basic Specification 10 B PIN Definition 11 C PIN Definition 11 5 Software Installation 12 A Install 12 Step 1 Execute the Setup exe file 12 Step 2 Select Destination Location 13 Step 3 Select Start Menu Folder 14 Step 4 Select Additional Tasks 15 Step 5 Processing 16 B Uninstall 17 Step 1 U...

Page 3: ...ep 2 Double click the selected item 21 Step 3 Configure and update your parameters 22 C By Direct Broadcast Commands 23 Command List A 23 Command List B 24 Command List C 25 7 Parameter Description 26 8 Application Notes 27 A Description 27 B Disable Firewall of Windows XP SP2 32 Step 1 Execute Windows Firewall 32 Step 2 Close the Firewall 33 C Make Program exception for Firewall 34 Step 1 Choose ...

Page 4: ...tem assumes no responsibility for any inaccuracies that may be contained in this document Infosystem makes no commitment to update or to keep current the information contained in this manual Infosystem reserves the right to make improvements to this document and or product at any time without notice No part of this publication may be reproduced stored in a retrieval system or transmitted in any fo...

Page 5: ... RS232 Ports to Ethernet Converter with Multi Sockets Warranty All products manufactured by Infosystem are warranted against defective materials for a period of one year from the date of delivery to the original purchaser Trademark The names used for identification only maybe registered trademark of their respective companies ...

Page 6: ...ings the user a lower cost TCP IP stack with limited functions Basically it supports most required protocol like ARP ICMP TCP UDP IP DHCP Client and even HTTP It supports 10 100M speed at Ethernet Port with Auto MDI MDIX and Multi Sockets Function Meanwhile it provides a faster speed on Serial Port than 115 2Kbps WS 125 product is small size and low cost solution It can convert serial port data to...

Page 7: ... 9 Support New Version Firmware Upgradeable Low cost and High Reliability 9 Cheap and stable 9 Working 24Hours per day Low Power Consumption 9 Less than 1W Power Consumption Support Necessary Network Protocols 9 ARP ICMP TCP UDP IP DHCP Client HTTP Support Various Interfaces Universal Set 9 RJ 45 x 1 10 100M Auto MDI MDIX 9 RS 232 1 D Sub 9 PIN RS 232 x 1 Faster than 115 2Kbps RTS CTS H W flow con...

Page 8: ... Multi Sockets C Applications Data collection Security Terminals Access Control Terminals Security Devices Time Recorders Warehouse Terminals Shop floor automation Terminals Remote Sensors and Various Meters Power monitors Power meters Environmental monitors Temperature monitors Data loggers Data Acquisitions Auto ID Scanners Barcode Scanners Magnetic Card Readers ...

Page 9: ...poration Ltd 6 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Exterior A Front View FRONT VIEW 24VDC RS 232 1 RS 232 2 RJ 45 FRONT VIEW 24VDC RS 232 1 RS 232 2 RJ 45 ...

Page 10: ...Copyright 2007 Infosystem Technology Corporation Ltd 7 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Exterior B Global View ...

Page 11: ... WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Exterior C Front Panel a 10 100M Ethernet Port b 24VDC Power c System LED Indicator d D Sub RS232 Connector e 3 PIN RS422 Connector b a c d e b a c d e D Dimension UNIT mm 4 xψ3 0 50 0 101 1 67 2 93 1 9 0 33 4 UNIT mm 4 xψ3 0 50 0 101 1 67 2 93 1 9 0 33 4 ...

Page 12: ...ED indication SYS Red high bright round LED LINK Green high bright round LED RX Green high bright round LED TX Red high bright round LED Power Power Supply 24VDC Environment Operating temperature 0 55 C non condensing Operating relative humidity 20 95 RH Storage temperature 10 70 C Mechanics Case Materiel ABS fire protection Mounting Surface mount wall mount Terminal block Plastic NYLON 66 Weight ...

Page 13: ...em Technology Corporation Ltd 10 WS 125 Preliminary 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 Specification B PIN Definition 24VDC RJ 45 10 100M Auto MDI MDIX RS 232 1 SYS LINK RX TX WS 125 RS 232 2 24VDC RJ 45 10 100M Auto MDI MDIX RS 232 1 SYS LINK RX TX WS 125 RS 232 2 ...

Page 14: ...tem Technology Corporation Ltd 11 WS 125 Preliminary 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 Specification C PIN Definition D sub RS 232 1 PIN RS 232 1 1 CD 2 RXD 3 TXD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS Male 9 RI Terminal Block RS 232 2 PIN RS 232 2 1 GND 2 NC 3 RXD 4 TXD ...

Page 15: ...th Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Install and Uninstall A Install Step 1 Execute the Setup exe file Execute the Setup exe file and you will get the following screen Press Next PS Press Ethernet Converter Setup Utilities button while using the installation cd ...

Page 16: ... WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Install and Uninstall A Install Step 2 Select Destination Location Select which directory you want to install the program Press Next ...

Page 17: ...25 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Install and Uninstall A Install Step 3 Select Start Menu Folder Select which folder you want the program to belong to of Start Menu Press Next ...

Page 18: ...oration Ltd 15 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Install and Uninstall A Install Step 4 Select Additional Tasks Create or not the extra icons Press Next ...

Page 19: ... Corporation Ltd 16 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Install and Uninstall A Install Step 5 Processing To start installation process press Install ...

Page 20: ...onverter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Install and Uninstall B Uninstall Step 1 Uninstall Ethernet Converter Execute Uninstall Ethernet Converter in the folder of where you have installed the program And then get the message as the following ...

Page 21: ...7 Infosystem Technology Corporation Ltd 18 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Configuration A By Browser Step 1 Ready to login ...

Page 22: ...system Technology Corporation Ltd 19 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Configuration A By Browser Step 2 Configure your parameters ...

Page 23: ...Infosystem Technology Corporation Ltd 20 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Configuration A By Browser Step 3 Finish and reboot ...

Page 24: ...orporation Ltd 21 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Configuration B By Setup Tools Step 1 Searching the devices Step 2 Double click the selected item ...

Page 25: ...Technology Corporation Ltd 22 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Configuration B By Setup Tools Step 3 Configure and update your parameters ...

Page 26: ...lows users to code their own application software Command List A User Level Command Description Notes Purpose For Broadcast search Syntax X magic code Magic code 99 130 83 99 Return AX MAC IP Device ID Send X 99 130 83 99 X or x Example Back AX 0 128 200 255 251 242 192 168 1 1 1 Purpose Get all the parameters of the WS 125 Syntax G MAC IP Setup Password Return All the parameters of the WS 125 Sen...

Page 27: ... Users Admin Level For Factory Default Setting Command List B User Level Command Description Notes Purpose Set the parameters of WS 125 Syntax S MAC IP Password Parameter Value A for accept Return C for cancel Send S 0 128 200 255 251 242 192 168 1 1 123 IP 192 168 1 2 S Example Back A or C Purpose Reboot WS 125 Syntax R MAC IP Setup Password AR for accept Return CR for cancel Send R 0 128 200 255...

Page 28: ...l For Factory Default Setting Command List C Admin Level Command Description Notes Purpose Set MAC of WS 125 then reboot automatically Syntax M Old MAC New MAC Factory Password AM for accept Return CM for cancel Send S 0 128 200 255 251 242 0 128 200 255 251 243 123 M Example Back A or C Purpose Set IP for Factory settings Syntax I MAC New IP Factory Password AI for accept Return CI for cancel Sen...

Page 29: ...o The default Subnet mask is 255 255 255 0 for Class C IP Ask your network administrator for assistance if in doubt Gateway IP The IP address of the router The default Gateway IP address is 192 168 1 254 Ask your network administrator for assistance if in doubt DHCP Client If this option is enabled that means the IP address Subnet mask and Gateway IP address of the WS 125 converter are set dynamic...

Page 30: ...on requests from the remote client device TCP Client The WS 125 converter will operate at the Active or the TCP Active mode to request establishing a TCP connection with the remote server device UDP Server The WS 125 converter will operate at the UDP Server mode to send and receive UDP datagram to from the remote device UDP Client The WS 125 converter will operate at the UDP Client mode to send an...

Page 31: ...er settings Baud Rate 300 bps to 115200 Parity None Even or odd Data Bits 7 or 8 Stop Bit 1 or 2 SIO Type Type of serial I O The serial interface types RS232 RS232 with RTS CTS control RS232 with RTS CTS DSR DTR control RS485 half duplex mode RS422 full duplex mode SIO Packets Gap SIO Inter Character Gap In some cases for example if the Modbus RTU serial protocol is used the completion of the mess...

Page 32: ...s used in TCP client mode or UDP client mode the Remote Host IP address must be specified to establish the connection with the designated HOST server only Remote Host Port If the WS 125 converter is used in TCP client mode or UDP client mode the Host Port No must be specified This is the port which the Remote Host IP listens for incoming data Slave Response Time Out Expected Time Out for the respo...

Page 33: ...ommunication will be disconnected by the WS 125 converter if there is no further TCP activity within the given timeout value Command Port The WS 125 converter supports the command mode which user can use to setup the parameters or get the information of the converter with UDP protocol from the remote host The default Command Port number is 65535 The command port of the WS 125 converter should be s...

Page 34: ...g password just leave the Setup password text box blank Access password If this password is configured the remote host needs to send this access password one second periodically to the Check Status Port of the WS 125 converter otherwise the data transfer request will not be accepted by the WS 125 converter To erase an existing password just leave the Access password text box blank Multi Sockets Ar...

Page 35: ... 2 RS232 Ports to Ethernet Converter with Multi Sockets Application Notes A Description Firewall will make the program off normal so one might choose the following solutions to Firewall program Disable or Exception B Disable Firewall of Windows XP SP2 Step 1 Execute Windows Firewall Execute Windows Firewall in Control Panel ...

Page 36: ...ion Ltd 33 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Application Notes B Disable Firewall of Windows XP SP2 Step 2 Close the Firewall Choose Close to close firewall ...

Page 37: ...S232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Application Notes C Make Program exception for Firewall Step 1 Choose Exception Choose Exception in Firewall Program And add on new program of Setup Tools ...

Page 38: ...25 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Application Notes C Make Program exception for Firewall Step 2 Add on New Program and Selection Choose Setup Tools to make it as an exception ...

Page 39: ...WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Application Notes C Make Program exception for Firewall Step 3 Allow Accept Any Computer Allow Accept Any Computer to finish exception ...

Page 40: ...ogy Corporation Ltd 37 WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets WS 125 2 RS232 Ports to Ethernet Converter with Multi Sockets Application Notes C Make Program exception for Firewall Step 4 Finished Finish Exception ...

Page 41: ...FAX 886 3 561 1435 Service E mail services infosystem com tw Web page URL http www infosystem com tw Infosystem Copyright 2007 Infosystem Technology Corporation Ltd No 45 Lane 167 Dongnan St Hsinchu Taiwan 300 R O C TEL 886 3 562 7187 FAX 886 3 561 1435 Service E mail services infosystem com tw Web page URL http www infosystem com tw ...

Reviews: