12_
installation
installation
Please take note of the followings before using this product.
•
Do not use the product outdoor.
•
Do not spill water or liquid in the connection part of the product.
•
Do not impose the system to excessive shock or force.
•
Do not pull out the power plug forcefully.
•
Do not disassemble the product on your own.
•
Do not exceed the rated input/output range.
•
Use a certified power cord only.
•
For the product with an input ground, use a grounded power plug.
CheCKing The inSTALLATion environmenT
This product is a top-notch security device that is equipped
with a high-capacity HDD and other key circuit boards.
Note that an excessive internal temperature of the product may
cause a system failure or a shortened product life (see the right
figure). Keep in mind the following instructions before installing
the product.
When mounting the product on a rack, comply with the following instructions.
1.
Please ensure that the rack inside is not sealed.
2.
Please ensure the air is circulated through the inlet/outlet as shown in the picture.
3.
If you pile up the prudcts or other rack-mount devices as shown in figure 2, secure room for
ventilation or install a vent.
4.
For natural air convection, place the inlet at the bottom of the rack and the outlet on top.
5.
It is strongly recommended that a fan motor is installed at the inlet and the outlet for air
circulation. (Please fit a filter at the inlet to screen dust or foreign substances.)
6.
Please maintain the temperature inside the rack or surrounding areas between 0°C ~ 40°C
(32°F ~ 104°F) as shown in the figure 1.
Rack Mount Instructions - The following or similar rack-mount instructions are included
with the installation instructions :
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the
manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
E) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should
be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
One Year: 24HR X 365 DAY =8,760 HR
Temperature
Unit: ºC
Life (Unit: HOURS)
[Figure 1]
PUSH
REC
1
2
3
4
5
6
7
8
9
10
11
12
ALARM
POWER
NETWO
RK
RAID
USB
HDD
PUSH
1
2
3
4
5
6
7
8
9
10
11
12
USB
PUSH
HDD
1
2
3
4
5
6
7
8
9
10
11
12
USB
HDD
PUSH
PUSH
[Figure 2]
PUSH
REC
1
2
3
4
5
6
7
8
9
10
11
12
ALARM
POW
ER
NETW
ORK
RAID
USB
HDD
PUSH
1
2
3
4
5
6
7
8
9
10
11
12
USB
PUSH
HDD
1
2
3
4
5
6
7
8
9
10
11
12
USB
HDD
PUSH
PUSH
Summary of Contents for SRN-4000
Page 1: ...NETWORK VIDEO RECORDER User Manual SRN 4000 ...
Page 141: ...Product Overview unit mm inches English _141 appendix ...
Page 165: ......