APPENDIX D
4618 - 021
133
Command
1,2
Direction
3
Description
Type
4
‘Q15,’ h ‘,’ m
‘Q15?’
in/out
in
Shift Report Interval Time
h = Two digit number, of the hour, in the range [0..24].
m = Two digit number, of the minute, in the range [0..59].
Maximum shift report interval time is 24:00
Shift Report Interval ?
X
‘Q16,’ h ‘,’ m
‘Q16?’
in/out
in
Shift Report Start Time
h = Two digit number, of the hour, in the range [0..23].
m = Two digit number, of the minute, in the range [0..59].
Maximum shift report start time is 23:59
Shift Report Start Time ?
X
‘Q17,’ h ‘,’ m
‘Q17?’
in/out
in
Test Interval
h = Single digit number, of the hour, in the range [0..8].
m = Two digit number, of the minute, in the range [0..59].
Maximum test interval time is 08:59
Test Interval ?
X
‘Q18,’ h ‘,’ m
‘Q18?’
in/out
in
Overdue Period
h = Single digit number, of the hour, in the range [0..4]
m = Two digit number, of the minute, in the range [0..59]
Maximum overdue period must be less than half of ‘Test
Interval and less than 04:59
Overdue Period ?
X
‘Q19,’ n
‘Q19?’
in/out
in
Alarm if Due/Overdue Setting
n = 0 : DUE
n = 1 : OVERDUE
Alarm if Due/Overdue Status ?
X
‘Q20,’ n ‘,’ o
‘Q20?’ n
in/out
in
QA Operator Number and Code
n = Operator number, a single digit number in the range
[1..9].
o = 4 digit code for the operator n, in the range [0..9999].
QA Operators code ?
X
‘Q21,’ n
‘Q21?’
in/out
in
Printer type
n = 0 : FIXED
n = 1 : PORTABLE
Printer type ?
X
NOTES
1
Those characters shown inside single quotes ‘ ’, are to be sent as shown in the identifier column. (ASCII
representation of characters is used).
2
xx?
is a request to the detector for information, (where
xx
is one of the identifiers in the identifier tables).
3
The direction that the identifier may be transmitted is with reference to the detector.
(
out
= transmitted by detector,
in
= received by detector ).
4
The “Type” field in the above table is used to categorise the identifiers into their sphere of influence.
Thus :-
F: Factory Setting.
X: Neither of the above.
P: Product-dependent setting.
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...