INSTALLATION
14
4618 - 021
Fig 9 Power Connections to the Detector
RATINGS
1)
RECOMMENDED MAINS LEAD
AREA 0.75
2
mm
CONSTRUCTION 24 x 0.2 mm
CURRENT RATING 6 AMP.
COLOURS BROWN-LIVE, BLUE-NEUTRAL,
GREEN/YELLOW-EARTH.
2)
a)
RECOMMENDED CIRCUIT BREAKER
DOUBLE POLE, CURRENT RATING 3 AMP
OR 4 AMP, TYPE C CIRCUIT BREAKER TO
BE MOUNTED CLOSE TO EQUIPMENT.
OR
b)
RECOMMENDED FUSE RATING
CURRENT RATING 4 AMP OR 5 AMP
ANTI-SURGE (T).