OPERATING INSTRUCTIONS
26
4618 - 021
Speed change guide
Introduction
This guide details in a step-by-step manner all settings that may have to be changed if the speed of
operation of the detector is changed.
NOTE
All of the following items may be set from the
Engineer Mode of operation
1)
‘Product speed’
on page 45.
2)
‘Vibration Setup’
on page 44
3)
‘Reject Timers’
and subsequent timer
sections on pages 42 and 78.
4)
‘Reject Confirmation’
on page 46.
5)
‘Product Number Settings Guide’
on
page 23.
Set up the speed of the product - either manually or
automatically.
Set up the detector to the vibration characteristics of
your system.
Set up the required timer groups to the appropriate
timer type and settings. Note this step is NOT
required for timers which are synchronised to the
product speed (e.g. tm3 and tm3G timer types).
If you are using the reject checking facilities of the
detector.
See the earlier guide.
How to... ‘Measure the speed of the product’
Step 1)
Enter the Engineer security code.
‘Entering security codes’
on page 19.
Step 2)
Select the Speed Setup Menu.
‘Speed Setup Menu’
on page 45
Step 3)
Select the ‘Auto Adjust’ feature and follow the
‘Product Speed’
on page 63.
instructions on the display.
Step 4)
On completion of step 3) the Product Speed
‘Product Speed’
on page 63.
display will show the current speed of the
product.
Step 5)
Press the PROG/EXIT key.
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...