OPERATING INSTRUCTIONS
4618 - 021
23
Product Number Settings Guide
Introduction
This guide should be performed for each product type that will be monitored by the detector.
The majority of products which have no product effect will operate on a single product number.
This guide sets all product-dependant settings of the detector.
NOTE
The ‘
Universal Settings Guide’
should be used
before this guide.
1)
‘Product Number and Automatic Setup’
on
page 43.
2)
‘Select and Update Timer’
on page 42.
3)
‘Inverse Detection’
on page 42.
4)
‘Automatic setup’
on page 50.
5)
‘Product Signal Cancellation’
on page 43.
6)
‘Automatic Tracking’
on page 45.
7) Go back to step 1) above for the next product to
be set up.
8)
‘Product Number and Automatic Setup’
on
page 40.
9)
‘Reject Inhibit’
on page 45.
NOTE
All of the following items may be set from the
Engineer Mode of operation.
Select the required product number to set up next.
Select the timer group for the product number.
If the product number is an inverse detect application
then select Inverse Detect.
Use the automatic facility of the detector to set the
phase and sensitivity.
If required then select the Product Signal Cancellation
feature.
If required then select the Automatic Tracking feature.
Finally change the product number to the product
number that is to be used next.
If this feature was enabled during
the ‘Universal
Settings Guide’
then disable it after completing this
guide.
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...