OPERATING INSTRUCTIONS
54
4618 - 021
VIBRATION SETUP
Introduction
This menu is used to set-up the detector for optimum
performance with any vibration present in the system.
NOTE
When adjusting the sensitivity limit ensure that all
mechanical and electronic equipment that may be a
source of vibration is operating (including reject
devices etc.).
Sensitivity limit
This display is used to manually or automatically set-
up the maximum sensitivity that will be set by the
automatic setup feature of the detector. The
maximum sensitivity must be reduced in situations
where the detector is subject to high vibration.
Press the soft key adjacent to sensitivity limit to
manually set the sensitivity limit. Press the ENTER
key when finished.
Press the soft key adjacent to Auto. Adjust to
automatically set the sensitivity limit.
NOTE
Remember to record all settings on the Settings
Sheets at the rear of the manual.