APPENDIX D
4618-021
132
Command Identifier - ‘Q’
QA Lists and Displays
All QA relevant displays (see ‘QA Operator Mode’ and ‘QA Inspector Mode’ flowcharts in the manual) will be
represented as a separate subseries from the main protocol letters. The elements of the subseries would be
identified by a number corresponding to the numbered position in the flowcharts mentioned. Thus the subseries
would be identified primarily by its letter ‘Q’ and then by its position within the ‘Q’ subseries by a number.
In the following table both the leading letter and the subseries element number are shown:
QA Operator commands
Command
1,2
Direction
3
Description
Type
4
‘Q01,’ m ‘,’ n
‘,’ o
‘Q01?’
in/out
in
Test Sample Material
m = product number
n = Sample
n = 0 : Ferrous
n = 1 : None - Ferrous
n = 2 : Stainless Steel
o = Test Result
o = 0 : Failed
o = 1 : Passed
Request last values of m, n, and o used by the detector.
P
‘Q02’ ....
’Q09’
-----------
Reserved for later use
X
QA Inspector commands
Command
1,2
Direction
3
Description
Type
4
‘Q10,’ n
in/out
Printing
n = 0 : Print(ing) all settings
n = 1 : Print(ing) shift reports
X
‘Q11,’ n
‘Q11?’
in/out
in
Line identification number
n = 4 digits number
Line Identification Number ?
X
‘Q12,’ n
‘Q12?’
in/out
in
Printer Selected
n = 0 : NO
n = 1 : YES
Printer selected ?
X
‘Q13,’ m ‘,’ n
‘,’ o
‘Q13?’ m ‘,’ n
in/out
in
Sample Size Registration
m = Product number, a two digit number in the range [0..20].
n = 0 : Ferrous Sample
n = 1 : None - Ferrous Sample
n = 2 : Stainless Steel Sample
o = Sample size in mm, a two digit number in the form X.X
(E.g. 09 = 0.9 mm
Sample Size Registration ?
P
‘Q14,’ n
‘Q14?’
in/out
in
Shift Report options
n = 0 : Reject Relay Operations OUT
Modified Settings
OUT
n = 1 : Reject Relay Operations OUT
Modified Settings IN
n = 2 : Reject Relay Operations IN
Modified Settings
OUT
n = 3 : Reject Relay Operations IN
Modified Settings IN
Shift Report options ?
X
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...