OPERATING INSTRUCTIONS
88
4618-021
tm2G TIMER - GATED MODE
!
CAUTION
Ensure you have read the REJECT TIMERS
INTRODUCTION section on page 78
Introduction
The tm2G gated timer is used to give precise
rejection of packaged or individual products.
The use of gating via a pack sensor ensures that the
rejection is independent of the position or size of the
metal contaminant within the product.
This timer type is suitable for reject devices which
include air-blast diverters, drop/lift flap diverters,
punch or pusher units etc.
Setting up timer type tm2G
The display opposite may be used to either:
1)
Select which timer group the current product
number should use,
or,
2)
Select which timer group the current product
number should use AND adjust the timer
group settings such as timer type, reject
time, signal
delay etc.
NOTE
REMINDER
If you have already selected the timer group and
pressed YES to updating the group, as per the
Engineer Mode section earlier, then proceed to
step 3).
1)
Press the soft key adjacent to the required
group letter, A, B or C.
NOTE
Remember to record all settings on the Settings
Sheets at the rear of the manual.
tm2G settings
1) Signal
Delay
2)
This is the time taken for a metal
contaminant to travel from the metal
detector to the reject device.
2)
Reject Time
This is the time required by the reject device
to
reject the contaminated product.
3)
Window time
This time is equal totwice the time a single pack
takes to pas by the pack sensor
This time is measured and calculated automatically
by the detector during the timer setup.
4)
Sync delay
This is the time taken for the pack to travel from the
pack sensor to the reject device.
The currently selected timer group will be indicated by a flashing
cursor appearing over the group letter.
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...