APPENDIX D
4618 - 021
123
Command
1 2
Direction
3
Description
Type
4
‘h’ n
‘h?’
in/out
in
Power-on / Reset flag
n = 0 : Flag is reset
n = 1 : Flag is set.
Note. This flag is
set
immediately after reset or power-on and is
only reset by the host sending the command, ‘h0’.
Power-on / Reset Occurred ?
X
‘I’ n
‘I?’
in/out
in
Reject Inhibit
n = 0 : NO
n = 1 : YES
Reject Inhibit ?
X
‘J’ n
‘J?’
in/out
in
Reject Confirmation.
n = 0 : NO
n = 1 : YES
Reject Confirmation ?
X
'j'
---------
SEE LATER FOR DETAILS OF IDENTIFIER 'j'
‘K’n
‘K?’
in/out
in
Reject Confirmation (Extension or Window) time.
n = Reject Confirmation window time, a four digit number in the
range [100...9900] - with timer types tm1, tm2 and tm2G,
[0 60000] - with timer types tm3 and tm3G, (all times in
milliseconds).
Reject Confirmation (Extension or Window) time ?
‘L’ n, o
‘L?’ o
in/out
in
Power high/low setting
n = product number, a two digit number in the range [0..20].
o = 0: LOW
n = 1: HIGH
Power high/low setting?
P
‘M’ n
in/out
Message number.
n = A four digit number, with leading zeroes, in the range
[0..9999].
This number is incremented for each message sent,
(wraparound to zero). The detector will treat consecutive
messages with the same message number as being a repeat
of each other.
X
‘N’ n
‘N?’
in/out
in
Language
n = 0 : English
n = 1 : French
...
n = 8 : Japanese
Language ?
X
‘O’n
‘O?’
out
in
Active mode
n = 0 : Running mode (no security code has been entered at the
keyboard)
n = 1 : Supervisor mode.
n = 2 : Engineer mode.
n = 3 : Viewing mode.
n = 4 : QA Inspector mode.
n = 5 : QA Operator 1 mode.
.
.
n = 13: QA operator 9 mode.
Which mode is active ?
X
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...