OPERATING INSTRUCTIONS
4618 - 021
97
10) Press the soft key adjacent to NO
11) The display shown opposite will appear for five
seconds before returning to the Engineer Mode
display.
Testing the Reject Device.
12)
a)
For packaged or separate products
i) Check the setting of tm3 by passing the
product and metal contaminant through the
aperture of the detector.
ii) Check the reject device operates correctly
with the metal contaminant at both the
front and rear of the pack.
iii) Check the reject device operates correctly
with different sizes of metal contaminant.
iv) Repeat i) to iii) above at the lowest and
highest speeds.