TECHNICAL SPECIFICATION
4618 - 021
5
TECHNICAL SPECIFICATION
Technology
High frequency low power electromagnetic coil
system - monitored and controlled by a
microprocessor system.
Frequency of Operation of Coil
Crystal controlled in the range 10 kHz to 1 MHz.
Multifrequency (optional) and single frequency units
are available.
Product throughput speed
Selectable.
Normal
0.1 to 2.0 m /min / mm of aperture height
(8 to 160 ft / min / inch of aperture height)
Variable
0.05 to 2.5 m / min / mm of aperture height
(4 to 200 ft / min / inch of aperture height)
Fast
0.05 to 7.5 m / min / mm of aperture height
(4 to 600 ft / min / inch of aperture height)
Higher and lower speeds are available on request.
Power Input
Voltage
100 to 240 Volts A.C..
+10% / -15%
Power
100 VA *
Frequency
50 to 60 Hz.
For connection to TN (EN60950:1992) power
distribution systems only. For connections to other
power distribution systems please contact your
supplier.
* Assumes no loads on the switched power outputs.
Internal Battery
Discharge time
typical 6 months from power
off
at temperature of 20
O
C
Battery life
typical 5 years
Nominal voltage
3.6 Volts D.C.
Temperature Range
Operating -10
°
C to +45
°
C (14
°
F to 110
°
F)
Storage
-10
°
C to +50
°
C (14
°
F to 120
°
F)
Humidity Range
Maximum relative humidity 93% for temperatures up
to 45
O
C.
Warm Up Time
Zero seconds at an ambient temperature of 20
°
C
Environmental Protection
Painted version
IP66, NEMA 4
Stainless steel version IP66, NEMA 4X
For more hostile environments a protective cover is
available for the control panel.
To achieve the specified protection the module and
power unit cover must be torqued down to 5 Nm
(45 in.lbs), or 4.5 Nm (40 in.lbs) for the module if the
environmental protection cover is used.
Sound Output
Less than 62 dBA at a distance of 1 m (without
printer).
Switched Power Output
Switched by detector ON/OFF switch.
Switched live and neutral, non-switched earth.
Not internally fused.
Maximum current
1 A
Reject Relay
Volt free changeover contacts that operate on the
detection of metal.
Maximum power
500 W
Maximum current
3 A (non-inductive)
Maximum voltage
250 Volts A.C., or
30 Volts D.C. (non-
inductive)
Summary of Contents for Signature
Page 16: ......
Page 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Page 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Page 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Page 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Page 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Page 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Page 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...