Accura 2350 Module ID Setup
Module ID Update
Module ID Status Display
cn(Communication)
1
Displays the number of updated modules that enable
communication
cF(Conflict)
2,4
Displays the number of modules with duplicate IDs by
automatically detecting them
to(Total)
3,4
Displays the total number of connected modules by
automatically detecting them
Module ID Update for Communication
IdUp(ID Update)
Updates module IDs by long pressing the Right(>)
arrow button
1. cn(Communication): Accura 2300S communicates with Accura 2350 in real time via the update of module IDs.
2. cF(Conflict): It indicates the number of Accura 2350 modules with duplicate ID(ID conflicts) or standby ID. These
modules cannot communicate with Accura 2300S.
3. to(Total): It indicates the number of Accura 2350 modules that are connected to Accura 2300S.
4. It is automatically displayed when Accura 2300S is connected to Accura 2350 modules.
Module ID
ID
Description
Communication ID
ID 0 - 39
ID of the module that enables communication
Conflict ID
Duplicate IDs There are more than 2 identical IDs. communication unavailable
Standby ID
1
ID 255
Module ID for checking connection status, communication unavailable
1. The standby ID 255 is assigned to all Accura 2350 modules as a factory default value.
Note
The non-zero number appearing next to the text
cF
blinks when two or more Accura 2350 modules
with duplicate IDs are detected or when an Accura 2350 module with the Standby ID exists.
①
Assign IDs to Accura 2350 modules again when there are Accura 2350 modules with
duplicate IDs.
②
After resolving ID conflicts, execute
IdUp
(Id Update) to update module IDs.
Automatic Assignment of Module IDs
The IDs
1
of Accura 2350 modules that enable communication can be automatically assigned in the
following four ways.
Setup Range
RJ-1 Inc2
Module ID increases by 2 starting from RJ-1. Refer to page 113.
RJ-2 Inc2
Module ID increases by 2 starting from RJ-2. Refer to page 113.
RJ-1 Inc1
Module ID increases by 1 starting from RJ-1. Refer to page 114.
RJ-2 Inc1
Module ID increases by 1 starting from RJ-2. Refer to page 114.
Stby
The IDs of all modules are initialized to the
standby ID.
Refer to page 115.
1. ID: 0
–
39, the IDs of the modules that enable communication