126
Connection
Description
Input
En
Output Q is set with a 0 to 1 signal transition at input En
(Enable) and if, in addition, 'Status=On' has been
confirmed in configuration mode.
Parameter
Type:
Sets either a pushbutton action for one cycle or a
switching action of the function.
Status
: On or Off state that is applied in the initial cycle
after program startup, is retentivity is not set.
Retentivity
set (on) = the status is retentive in memory.
Output
Q
Output Q remains set 1, as long as En=1 and the status at
the parameter Type = Switch and Status = On.
Output Q is set for the duration of one cycle if EN=1 and the
status at the parameters Type = momentary (pushbutton)
and Status = On.
Factory state
Default of 'Type' is 'momentary action switch'.
Timing diagram
Description of the function
The output is set, when input En is set and the 'Status' parameter is set to 'On' and confirmed with OK.
This action is performed irrespective of a configured switch or pushbutton function.
The output is reset to '0' in the following three cases:
With a 1 to 0 signal transition at input En.
When a pushbutton function is configured and one cycle has expired after its
actuation.
When the 'Status' parameter sets the 'Off' status in configuration mode, and this
has been confirmed with OK.
Particular characteristics to be noted when configuring
The softkey can be used both with momentary push button or switching action. At the status parameter
you can define the on (actuated) or off state for the switch/push button.
If the softkey is assigned a push button action, the output is always set for the duration of one cycle with
a 0 to 1 transition at input En when the push button is in on state, or if the push button state changes
from Off to On when En=1.
Summary of Contents for ELC-12AC-R-N
Page 1: ...Applied to ELC PR series Ver 3 0 Programmable Relay User s Manual Rievtech Electronic Co Ltd...
Page 27: ...27 PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension PR 24 series...
Page 31: ...31 AC type digital inputs Analog Inputs DC 0 10V Analog inputs current Inputs 0 20mA...
Page 40: ...40...
Page 120: ...120 C Analog input value of CPU and extensions D Analog output value of CPU and extensions...
Page 121: ...121 E F digital flag status F AF analog flag value...
Page 122: ...122 G M status H AM value...
Page 221: ...221 7 Click Install button to install Program is being installed...
Page 250: ...250...
Page 256: ...256 You can read the parameters from the PLC...
Page 258: ...258...
Page 267: ...267 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Page 268: ...268 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Page 269: ...269 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Page 290: ...290 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Page 317: ...317 Network settings You can view the network parameters in such table...
Page 331: ...331 B005 Read the I1 IA status from the slave1 to the F11 F20 of the master Setting as follows...
Page 332: ...332 B006 Read the I1 IA status from the slave2 to the F21 F30 of the master Setting as follows...
Page 346: ...346 7 4 2 The scheme of xLogic The circuit diagram of industry gate...
Page 353: ...353 7 6 2 The scheme of xLogic Components K1 main contactor...
Page 357: ...357 4 cursors Cursor key Type 1x MODBUS code 02 C1 C4 256 259 BIT R...
Page 392: ...392...