181
2. Record title
Below is an example in the “OUTPUT.TXT”
The above range circled in red is just pre-set contents in the “Record title” of the Memory write block’s
property dialog box.
2. File write mode
Two options available: Option A. Append (This option would be selected if a certain file is already existed
in the Mini SD card inserted in ELC -MEMORY)
B . Create ( This option shall be chosen, if no any file existed or existed file has different name from that
pre-set in the “file name” in the Mini SD card inserted in ELC-MEMORY
If such
box has been ticked ,the file content will show the time when the data starts to be recorded.
4. Separator
Such separator shall be required while more than one analog values would be stored and displayed for
easier observation and convenient analysis.
5. File Size
It is an option for you to set the size of file to be stored.
6. After memory Full
Two options can be selected after memory is full (it means the relative file has reached its pre-configured
size), one is to over-write and the other is to stop recording.
7. Register params:
This section is for register’s parameters setting. The register includes following sorts:
A. I digital inputs
Name
Address:
I1-I8
0….7
I11-I14
8---15
I21-I24
16…23
…..
……
B. Q digital outputs
Summary of Contents for ELC-12AC-R-N
Page 1: ...Applied to ELC PR series Ver 3 0 Programmable Relay User s Manual Rievtech Electronic Co Ltd...
Page 27: ...27 PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension PR 24 series...
Page 31: ...31 AC type digital inputs Analog Inputs DC 0 10V Analog inputs current Inputs 0 20mA...
Page 40: ...40...
Page 120: ...120 C Analog input value of CPU and extensions D Analog output value of CPU and extensions...
Page 121: ...121 E F digital flag status F AF analog flag value...
Page 122: ...122 G M status H AM value...
Page 221: ...221 7 Click Install button to install Program is being installed...
Page 250: ...250...
Page 256: ...256 You can read the parameters from the PLC...
Page 258: ...258...
Page 267: ...267 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Page 268: ...268 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Page 269: ...269 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Page 290: ...290 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Page 317: ...317 Network settings You can view the network parameters in such table...
Page 331: ...331 B005 Read the I1 IA status from the slave1 to the F11 F20 of the master Setting as follows...
Page 332: ...332 B006 Read the I1 IA status from the slave2 to the F21 F30 of the master Setting as follows...
Page 346: ...346 7 4 2 The scheme of xLogic The circuit diagram of industry gate...
Page 353: ...353 7 6 2 The scheme of xLogic Components K1 main contactor...
Page 357: ...357 4 cursors Cursor key Type 1x MODBUS code 02 C1 C4 256 259 BIT R...
Page 392: ...392...