Standard Modbus RTU/ASCII/TCP communication protocol supported.
It’s optional for xLogic to act as slave or master in certain Modbus communication network.
(easy connect to other factory touch screen by RS232 cable, RS485 module)
CAN BUS protocol based expansion modules(PR-18/PR-24 series CPU)
Expandable up to 16 linked IO expansion modules reaching 282 I/O points in maximum
Optional RS232, RS485 and Ethernet connectivity
Multiple channels analog inputs available with DC 0-10V signal ,PT100 signal& 0/4….20mA.
Default Real Time Clock (RTC) and summer/winter timer is available
Backup at Real Time Clock (RTC) at 25 °C:20 days
4 channels high-speed counting
Pre-configured standard functions, e.g. on/ off-delays, pulse relay and softkey
2 PWM channels(10KHz in maximum)
Retentive memory capability (Not applied to PR-6&PR-12-E series CPU)
RS232 and USB communication download cable with photo-electricity isolation
Programmable capability up to 1024 function blocks(PR-18/PR-24);512 function
blocks(PR-12&ELC-12-N) and 64 function blocks for PR-6&PR-12-E
Mounting via modular 35mm DIN rail or screw fixed mounting plate
On-line monitor capability(Free charge SCADA for all series xlogic)
Datalogging
Kinds of analog signals process capacity (DC 0..10V ,0/4...20mA and PT100 probe inputs and DC
0..10V and 0/4...20mA outputs)
Low cost
Some of the things xLogic can do for you?
The xLogic Micro PLC provides solutions for commercial, industrial, building and
domestic applications such as lighting, pumping, ventilation, shutter operations or
in switching cabinets. The application field is widespread and these are just a few to mention.
Using the RS485 bus and Ethernet connectivity allows the user to realize various extensive (real-time)
monitoring and control applications.
Special versions without operator panel and display unit are available for series production applications
in small machine, installation and cabinet building environments to further slash cost.
xLogic devices
:
xLogic Basic is available in two voltage classes:
*Classes 1:DC12-24V: i.e.: PR-6DC Series, PR-12DC series, PR-18 series, PR-24DC series.
Summary of Contents for ELC-12AC-R-N
Page 1: ...Applied to ELC PR series Ver 3 0 Programmable Relay User s Manual Rievtech Electronic Co Ltd...
Page 27: ...27 PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension PR 24 series...
Page 31: ...31 AC type digital inputs Analog Inputs DC 0 10V Analog inputs current Inputs 0 20mA...
Page 40: ...40...
Page 120: ...120 C Analog input value of CPU and extensions D Analog output value of CPU and extensions...
Page 121: ...121 E F digital flag status F AF analog flag value...
Page 122: ...122 G M status H AM value...
Page 221: ...221 7 Click Install button to install Program is being installed...
Page 250: ...250...
Page 256: ...256 You can read the parameters from the PLC...
Page 258: ...258...
Page 267: ...267 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Page 268: ...268 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Page 269: ...269 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Page 290: ...290 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Page 317: ...317 Network settings You can view the network parameters in such table...
Page 331: ...331 B005 Read the I1 IA status from the slave1 to the F11 F20 of the master Setting as follows...
Page 332: ...332 B006 Read the I1 IA status from the slave2 to the F21 F30 of the master Setting as follows...
Page 346: ...346 7 4 2 The scheme of xLogic The circuit diagram of industry gate...
Page 353: ...353 7 6 2 The scheme of xLogic Components K1 main contactor...
Page 357: ...357 4 cursors Cursor key Type 1x MODBUS code 02 C1 C4 256 259 BIT R...
Page 392: ...392...