374
Programming cable
PC cable, (RS232 or USB)
Third party device(HMI)
<=> xLogic
Yes (work as modbus master or slave)
Extensions
No
High speed input
No
I5---I8(60kHz)
HMI
Yes
RS485 port
Option1:Can use PRO-RS485 cable to convert program port to RS485 port
Standard CPU Units
(PR-18 series)
PR-14AC-R
PR-14DC-DA-R
Power supply:
Nominal voltage
AC110V-240V
DC 12-24V
Operating limits
AC85 - 265 V
DC 10.8-28.8V
Immunity from micro
power cuts
---
Typ. 5 ms
Max. Startup current
---
Max. 0.25A
Max. absorbed power
49mA (85V ac) ;
37mA (265V ac)
3.5 W (10.8V dc) ;
4 W (28.8V dc)
Protection against polarity
inversions
Yes
Yes
The main frequency range
47-63Hz
---
Input parameters:
Input No
10 ( I1-IA )
10 (I1-IA )
Digital input
10 ( I1-IA )
10 (I1-IA )
Analogue input
None
6 ( I1-I6)(0..10V DC)
Input voltage
AC0-240V
DC 0-28.8V
Input signal0
AC0-40V
;
<0.03mA
< 5V DC;<0.1mA(I1-I6),<1mA(I7-IC)
Input signal1
AC79-240V
;
>0.06mA
> 8 V DC;>0.3mA(I1-I6),>1.7mA(I7-IC)
Input current
---
0.4mA(I1-I6),2.3mA(I7-IC),@ 10.8V dc
0.5mA(I1-I6),2.6mA(I7-IC),@ 12.0 V dc
1.2mA(I1-I6),5.2mA(I7-IC),@ 24 V dc
1.5mA(I1-I6),6.3mA(I7-IC),@ 28.8 V dc
Input Response Time
Delay time at 0 to 1
:
120V AC
:
Typ. 50 ms
240V AC
:
Typ. 30 ms
Delay time at 1 to 0
:
120V AC
:
Typ. 90 ms
240V AC
:
Typ.100 ms
Delay time at 0 to 1
:
Typ. 1.5 ms (I1-I6),<1ms(I7-IC)
;
Delay time at 1 to 0
:
Typ. 1.5 ms(I1-I6),<1ms(I7-IC)
;
Maximum counting
frequency
Typ. 4Hz
Typ.
:
4 HZ
Sensor type
Contact or 3-wire PNP
Contact or 3-wire PNP
Isolation between power
supply and inputs
None
Resistive
Summary of Contents for ELC-12AC-R-N
Page 1: ...Applied to ELC PR series Ver 3 0 Programmable Relay User s Manual Rievtech Electronic Co Ltd...
Page 27: ...27 PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension PR 24 series...
Page 31: ...31 AC type digital inputs Analog Inputs DC 0 10V Analog inputs current Inputs 0 20mA...
Page 40: ...40...
Page 120: ...120 C Analog input value of CPU and extensions D Analog output value of CPU and extensions...
Page 121: ...121 E F digital flag status F AF analog flag value...
Page 122: ...122 G M status H AM value...
Page 221: ...221 7 Click Install button to install Program is being installed...
Page 250: ...250...
Page 256: ...256 You can read the parameters from the PLC...
Page 258: ...258...
Page 267: ...267 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Page 268: ...268 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Page 269: ...269 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Page 290: ...290 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Page 317: ...317 Network settings You can view the network parameters in such table...
Page 331: ...331 B005 Read the I1 IA status from the slave1 to the F11 F20 of the master Setting as follows...
Page 332: ...332 B006 Read the I1 IA status from the slave2 to the F21 F30 of the master Setting as follows...
Page 346: ...346 7 4 2 The scheme of xLogic The circuit diagram of industry gate...
Page 353: ...353 7 6 2 The scheme of xLogic Components K1 main contactor...
Page 357: ...357 4 cursors Cursor key Type 1x MODBUS code 02 C1 C4 256 259 BIT R...
Page 392: ...392...