Congratulations with your xLogic Micro PLC provided by Rievtech Electronic Co., Ltd.
The xLogic Micro PLC is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and
counters.
The xLogic Micro PLC perfectly fits in the space between timing relays and low-end PLCs. Each CPU
incorporates not only a real-time clock and calendar, but also provides support for optional expansion I/O
modules to enhance control and monitoring applications. Data adjustments can easily be performed via
the keypad, the LCD display, or through the Rievtech-to-use xLogic soft. DIN-rail and panel-mounted
options are both available, offering full flexibility to the various installation needs of your application.
The xLogic Micro PLC is available in 120V/240V AC or 12V and 24V DC versions, making it the ideal
solution for relay replacement, or simple control applications as building and parking lot lighting,
managing automatic lighting, access control, watering systems, pump control, ventilation systems,
home automation and a wide field of other applications demanding low cost to be a primary design issue.
We strongly recommended taking the time to read this manual, before putting the xLogic Micro PLC to
work. Installation, programming and use of the unit are detailed in this manual. The feature-rich xLogic
Micro PLC provides a for off-line operation mode, allowing full configuration and testing prior to in-field
service commissioning. In reviewing this manual you will discover many additional advantageous product
properties, it will greatly simplify and optimize the use of your xLogic Micro PLC.
Valid range of this manual
The manual applies to devices of ELC series and PR series modules . For more information about EXM
series module(GSM and WIFI module) ,please refer to the x-Messenger user's manual.
Safety Guideline
This manual contains notices you have to observe in order to ensure your personal safety, as well as to
Summary of Contents for ELC-12AC-R-N
Page 1: ...Applied to ELC PR series Ver 3 0 Programmable Relay User s Manual Rievtech Electronic Co Ltd...
Page 27: ...27 PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension PR 24 series...
Page 31: ...31 AC type digital inputs Analog Inputs DC 0 10V Analog inputs current Inputs 0 20mA...
Page 40: ...40...
Page 120: ...120 C Analog input value of CPU and extensions D Analog output value of CPU and extensions...
Page 121: ...121 E F digital flag status F AF analog flag value...
Page 122: ...122 G M status H AM value...
Page 221: ...221 7 Click Install button to install Program is being installed...
Page 250: ...250...
Page 256: ...256 You can read the parameters from the PLC...
Page 258: ...258...
Page 267: ...267 TCP Sever 192 168 0 227 port 8004 is ok TCP Sever 192 168 0 227 port 8005 is ok...
Page 268: ...268 TCP Sever 192 168 0 227 port 8006 is ok TCP Sever 192 168 0 227 port 8007 is ok...
Page 269: ...269 TCP Sever 192 168 0 227 port 8008 is ok TCP Sever 192 168 0 227 port 8009 is ok...
Page 290: ...290 Slave1 IP 192 168 0 101 TCP server port 8001 Slave2 IP 192 168 0 102 TCP server port 8002...
Page 317: ...317 Network settings You can view the network parameters in such table...
Page 331: ...331 B005 Read the I1 IA status from the slave1 to the F11 F20 of the master Setting as follows...
Page 332: ...332 B006 Read the I1 IA status from the slave2 to the F21 F30 of the master Setting as follows...
Page 346: ...346 7 4 2 The scheme of xLogic The circuit diagram of industry gate...
Page 353: ...353 7 6 2 The scheme of xLogic Components K1 main contactor...
Page 357: ...357 4 cursors Cursor key Type 1x MODBUS code 02 C1 C4 256 259 BIT R...
Page 392: ...392...