PC0144 Relay
Quick Start Guide
1.
To securely mount the device on a flat surface, M4 screws and nuts can
be applied at the side of the enclosure. (Not provided in the box)
2.
If connecting multiple PanL Relays to a single PanL Hub port in a daisy
chain configuration, set the ID switch. Refer to the section -
ID Switch
Configuration
for details.
3.
Connect RJ45 8P8C cable and add a terminator. Refer to the section
PanL Hub Connection
for details.
4.
If using
Relay (RL1-RL4)
option, refer to the section
Relay (RL1-
RL4) Setup
for details.
5.
If using
SSR Control
option, refer to
SSR Control
setup
for details.
6.
If using
DC INPUT
for external input sense
,
refer to the section
DC
Input
setup for details.
For multiple PanL Relay connections to a single PanL Hub port, the ID switch
at the back of the displays must be configured to be unique. Using a Philip
head screw driver, set a unique number for each display between 0-7 (do
not use 8-9). For example, if connecting 3 PanL Relay to a PanL Hub port,
you may set it as 0, 1, and 2. Relays connected to different PanL Hub ports
can share the same unique number.
The PanL Relay is designed to be connected to a PanL Hub for power and data
via the P1 or P2 RJ45 ports. When a single PanL Relay is connected to a PanL
Hub port, the maximum length of the RJ45 cable shall not exceed 100 meters.
Connect the PanL terminator (provided in the PanL Hub package) to the
unconnected P1 or P2 port.
For multiple PanL Relay connections to a single PanL Hub port, the first
connection to PanL Hub and the subsequent connections in between the PanL
Relay devices must not exceed 50 meters in cable length each. A single PanL
Hub port can support up to 3 PanL Relay. The total combined cable lengths
must not exceed 100 meters. Connect the PanL terminator provided in PanL
Hub box to the last unconnected PanL Relay P1 or P2 port.
Product Features
PanL Relay
ID Switch Configuration
PanL Relay Setup
Relay (RL1-RL4) Setup
Please visit
QR
code
for warranty registration with the UUID and Product Key
below:
STICKER AREA
The Relay (RL1-RL4) supports both AC and DC Loads and is rated at
AC250V/DC28V/10A max per relay. Below depicts 2 connection options:
DEVICES NORMALLY OFF (NO)
DEVICES NORMALLY ON (NC)
WARNING: ALWAYS SWITCH OFF POWER SUPPLY WHEN WIRING
1
Power Indicator
2
RJ45 Ports
–
Connect PanL Hub, another PanL Device or
Terminator
3
ID Switch
–
Refer to the
ID Switch Configuration
section
for more details
4
Status indicator
- Refer to the
PanL Relay LED Status
Indicator
section for more details
5
USB
–
Reserved for factory use only
6
1W
–
Reserved for factory use only
7
Reset Button
8
DC Input/Solid State Relay (SSR) Control
–
Refer to DC Input and SSR Control setup section for more
details
9
Relay Ports (RL1-RL4)-
Refer to Relay(RL1-RL4) setup section for more details
PanL Hub Connection
DC Input Setup
The 4 DC input channels are designed to take in external DC inputs ranging
from 3.3V to 24V. It can be used as a feedback channel to sense the RL1-
RL4 and SSR activation. Setup connections are illustrated below: