background image

PC0144 Relay 
Quick Start Guide 

1.

 

To securely mount the device on a flat surface, M4 screws and nuts can 
be applied at the side of the enclosure. (Not provided in the box) 

2.

 

If connecting multiple PanL Relays to a single PanL Hub port in a daisy 
chain configuration, set the ID switch. Refer to the section - 

ID Switch 

Configuration

 for details. 

3.

 

Connect  RJ45  8P8C  cable  and  add  a  terminator.  Refer  to  the  section 

PanL Hub Connection

 for details. 

4.

 

If  using 

Relay  (RL1-RL4) 

option,  refer  to  the  section 

Relay  (RL1-

RL4) Setup 

for details.  

5.

 

If using 

SSR Control

 option, refer to 

SSR Control 

setup

 for details. 

6.

 

If  using 

DC  INPUT 

for  external  input  sense

,

  refer  to  the  section 

DC 

Input 

setup for details. 

 

 

For multiple PanL Relay connections to a single PanL Hub port, the ID switch 
at the back of the displays must be configured to be unique. Using a Philip 
head screw driver, set a unique number for each display between  0-7 (do 
not use 8-9). For example, if connecting 3 PanL Relay to a PanL Hub port, 
you may set it as 0, 1, and 2. Relays connected to different PanL Hub ports 
can share the same unique number. 

The PanL Relay is designed to be connected to a PanL Hub for power and data 
via the P1 or P2 RJ45 ports. When a single PanL Relay is connected to a PanL 
Hub port, the maximum length of the RJ45 cable shall not exceed 100 meters. 
Connect  the  PanL  terminator  (provided  in  the  PanL  Hub  package)  to  the 
unconnected P1 or P2 port.   
 
 
 
 
 
 
 
 
 
 

 

For  multiple  PanL  Relay  connections  to  a  single  PanL  Hub  port,  the  first 
connection to PanL Hub and the subsequent connections in between the PanL 
Relay devices must not exceed 50 meters in cable length each. A single PanL 
Hub port can support up to 3 PanL Relay.  The total combined cable lengths 
must not exceed 100 meters. Connect the PanL terminator provided in PanL 
Hub box to the last unconnected PanL Relay P1 or P2 port.    

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Features 

  

PanL Relay 

ID Switch Configuration 

PanL Relay Setup 

Relay (RL1-RL4) Setup 

Please  visit 

http://panlshop.com/warranty

  or  scan  the 

QR 

code

 for warranty registration with the UUID and Product Key 

below:  

 

 

STICKER AREA 

The  Relay  (RL1-RL4)  supports  both  AC  and  DC  Loads  and  is  rated  at 
AC250V/DC28V/10A max per relay. Below depicts 2 connection options:  
 
DEVICES NORMALLY OFF (NO)  
 
 
 
 
 
 
 

DEVICES NORMALLY ON (NC)

 

 

 

 

   

WARNING: ALWAYS SWITCH OFF POWER SUPPLY WHEN WIRING

 

 

1

 

Power Indicator

 

RJ45 Ports

 

 Connect PanL Hub, another PanL Device or 

Terminator

 

ID Switch

 

 Refer to the

 ID Switch Configuration

 section 

for more details

 

Status indicator

 - Refer to the

 PanL Relay LED Status 

Indicator 

section for more details 

USB

 

 Reserved for factory use only

 

1W

 

Reserved for factory use only 

Reset Button

 

DC Input/Solid State Relay (SSR) Control

 

Refer to DC Input and SSR Control setup section for more 
details 

Relay Ports (RL1-RL4)-  

Refer to Relay(RL1-RL4) setup section for more details   

 

PanL Hub Connection 

DC Input Setup 

 

The 4 DC input channels are designed to take in external DC inputs ranging 
from 3.3V to 24V. It can be used as a feedback channel to sense the RL1-
RL4 and SSR activation. Setup connections are illustrated below:  