FAULT
CAUSE
REMEDIES
Reduced vacuuming capacity
Clogged primary filter
Clean or replace the filter
Broken seals or worn out
Change the seals
Container not closed tight
Check condition of the seals
Clogged suction hose
Clean the hose
Suction hose not completely
connected to
Check hose connection
The waste bin is full
Empty the container
Vacuuming completely missed
Missing of power supply
Check that electric power
reaches the electrical panel
The motor is burned out
Check the reasons why and
replace the motor
Electrical connections are
disconnected
Check electrical connections and
connect them
Voltage not correct
Check the data shown in the
identification plate and, if
needed, contact the nearest After
Sales Service
FAULTS, CAUSES, REMEDIES
The indications described in the
table have got the aim to help
the users in finding out possible
troubleshooting.