Chapter 5 Administration
Introduction
Quantum SuperLoader 3 User’s Guide
67
Introduction
When you first power on the Quantum SuperLoader 3 autoloader, it
automatically runs a power on self-test (POST). During the POST, the left
(green) LED flashes. After the POST, the left (green) and right (amber)
LED flash alternately back and forth. Do one of the following:
• If the autoloader powers on successfully, continue configuring the
autoloader (see
Configuring the Autoloader
).
• If the autoloader does not power on successfully, check the following:
• Power switch is on.
• Power cable is inserted correctly.
• SCSI (or SAS, or Fibre Channel) cable is connected to the
autoloader and host computer.
• SCSI bus is terminated (SCSI autoloader).
• No error code displays on the autoloader LCD.
• If you cannot resolve the problem yourself, contact your service
representative or go to
www.quantum.com
.
When you first power on the autoloader, the setting for the Internet
Protocol (IP) address is static with the address
192.168.20.128
. If you want
to use Dynamic Host Configuration Protocol (DHCP) to change the IP
address, see
“Setting the IP Address”
on page 72. To determine the IP
address when using DHCP, view the Ethernet status information (see
“Viewing Ethernet Information”
on page 45).
Note:
The front panel requires a six-digit password to change the
configuration (see
“Setting Passwords”
on page 79). The
LCD front panel default password for the Administrator is
000000
. The default password for the Operator is
111111
.