Chapter 2 Installation and Configuration
Choosing a Location
Quantum SuperLoader 3 User’s Guide
10
Choosing a Location
The autoloader is designed to fit in a standard 19-inch rack using either
the long or short brackets (depending on the depth of the rack). Choose a
location that meets the following criteria (see
appendix A, Specifications
).
The autoloader uses standard rack mounting hardware.
Table 1 Location Criteria
Criteria
Description
Rack requirements
Standard 19-inch rack with 2U of clearance.
Room temperature
10–35° C (50–95° F)
Power source
AC power voltage: 100–127 VAC; 200–240 VAC
Line frequency: 50–60 Hz
Note:
Locate the AC outlet near the autoloader. The AC power cable is the
product’s main disconnect device and must be easily accessible at all
times.
Weight
14.1 kg (31 lb) unloaded
17.2 kg (38 lb) loaded with 2 magazines, 16 cartridges
Air Quality
Minimize sources of particulate contamination. Avoid areas near frequently
used doors and walkways, cooling or exhaust vents, stacks of supplies that
collect dust, printers, and smoke-filled rooms.
Caution:
Excessive dust and debris can damage tapes and tape drives.
Humidity
20–80% RH (non-condensing)
Clearance
Back: Minimum of 43.2 cm (17 in.)
Front: Minimum of 68.6 cm (27 in.)
Sides: Minimum of 5.08 cm (2 in.)