Chapter 6 Diagnostics
Power-on Self Test (POST)
Quantum SuperLoader 3 User’s Guide
83
Performing a POST
6
If you experience errors while operating your autoloader, you may need
to reboot the autoloader to perform a POST.
To reboot the SuperLoader 3 autoloader:
1
Hold down the power button until the
System Shutdown Please
Wait...
message displays.
2
Release the power button. The autoloader turns off.
3
Press the power button again to turn the autoloader on. POST runs
automatically.
Interpreting the POST
Results
6
While the POST is running, a progress indicator showing the name of the
test displays on the front panel. If the autoloader is working properly, the
message
System Ready
and the current configuration display after the
POST completes successfully.
If the autoloader is not working properly, error messages display on the
front panel (see
“Autoloader Logs”
on page 106).
MDM
Verifies that the MDM is present and checks the sensors
Fan
Verifies that the fan is operating correctly
POST Test
Description