7.6 Carriage PCBA
P/N 500627-01-3
Tools Required:
•
Number 1 Phillips Screwdriver
The Carriage Assembly must be removed before replacing the Carriage PCBA.
BCR
Barcode Reader
Mounting Plate
Barcode Reader
Mounting Plate
Screws (4)
Barcode Reader
PCBA Mounting Screws (4)
MOTORZ
CRTEMT
CRTDET
GRIPA
GRIPB
MOTORY
CARAGE
CRTDET
Cable
Carriage PCBA
Hole for Vertical (Y) Axis
Home Sensor Probe
Cable Clamps (2)
Figure 7-10 Carriage PCBA (Handler Bottom View)
7.6.1 Carriage PCBA Removal
1.
Remove the Carriage Assembly (see Section 7.5.1 for details).
2.
If the Carriage Assembly is equipped with a Barcode Reader, unplug the cable at
the BCR connector on the Carriage PCBA.
3.
Remove all four Barcode Reader mounting plate screws using a number 1 Phil-
lips screwdriver.
4.
Unplug the cable at the CRTEMT connector on the Carriage PCBA and move the
cable aside.
5.
Remove the Barcode Reader Mounting Plate. (It is not necessary to remove the
Barcode Reader before removing the Barcode Reader Mounting Plate.)
6.
Unplug the motor cables from the MOTORY and MOTORZ connectors.
7.
Unplug the cable from the CRTDET connector.
7-16
Field–Replaceable Units (FRUs)
501380 Rev. B