6.
The library is configured for the wrong TLS model.
7.
If the location is a tape drive, the drive is configured to the wrong type.
8.
The calibration data is corrupt and the library needs to be recalibrated.
9.
The Insertion Axis is binding near the magazine end of its travel.
6.2.8 During operation, the alert
Handler Jammed
appears on the control
panel display.
Possible causes:
1.
The Insertion Axis is binding.
2.
The Insertion Axis is jammed against a stop.
3.
The Insertion Axis motor is unplugged.
4.
If the location is a tape drive, the drive is configured to the wrong type.
5.
The Insertion Axis has a tape jammed against the I/O Slot.
6.
The Insertion Axis motor system has malfunctioned.
6.2.9 During operation, the alert
Vertcl Axis Jammed
appears on the control
panel display.
This occurs when the carriage attempts to move vertically but is unable.
Possible causes:
1.
The carriage is jammed by a cartridge and unable to move freely up or down.
2.
A magazine is not seated properly and is colliding with the carriage.
3.
A cartridge is hanging off the carriage and is colliding with a magazine or tape
drive.
4.
The I/O port is interfering with the carriage.
5.
The Vertical Axis motor system has failed.
6.
The Vertical (Y) Axis leadscrew is binding.
7.
The Vertical Axis leadscrew is not attached properly at both ends.
8.
The library is configured to the wrong model, and the carriage is colliding with
the top of the library.
501380 Rev. B
Troubleshooting
6-13