![Qualstar TLS-4000 Technical & Service Manual Download Page 124](http://html1.mh-extra.com/html/qualstar/tls-4000/tls-4000_technical-and-service-manual_3421438124.webp)
7.13 Tape Drive Power Supplies
DANGER
TO AVOID THE RISK OF PERSONAL INJURY, ALWAYS WAIT ABOUT ONE MIN-
UTE AFTER THE POWER IS TURNED OFF AND THE POWER CORD IS DISCON-
NECTED, BEFORE TOUCHING THE HANDLER POWER SUPPLY OR THE TAPE
DRIVE POWER SUPPLY.
GEFAHR
UM VERLETZUNGEN ZU VERHINDERN WARTEN SIE BITTE 1 MINUTE NACH-
DEM SIE DEN STROM AUSGESCHALTET HABEN UND DAS STROMKABEL ENT-
FERNT HABEN, BEVOR SIE DAS HANDLER-NETZTEIL SOWIE DAS TAPE-DRIVE-
NETZTEIL BERUEHREN.
40W P/N 500826-02-9
110W P/N 500826-03-7
125W P/N 500826-12-8
Tools Required:
•
Number 2 Phillips Screwdriver
7.13.1 Tape Drive Power Supply Removal
NOTE
To determine which model of Tape Drive power supply is installed in the library , remove the
top and right side panels then read the Tape Drive Power Supply Label located on the power
supply. See Figure 7-27. The label will read 500826-xx-x. Make sure that the replacement power
supply has the same part number (or its equivalent) as the one that is to be removed.
1.
Turn off the TLS power and remove the power cord.
2.
Remove the Top Panel (Section 7.4.1).
3.
Remove the right Side Panel, as seen from the front of the TLS (Section 7.4.3).
4.
Remove all four protective Screen mounting screws (Figure 7-27).
5.
Disconnect the Power Cable and the 2-Wire Cable connectors from the Power
Supply PCBA (Figure 7-27).
7-42
Field–Replaceable Units (FRUs)
501380 Rev. B