![Qualstar TLS-4000 Technical & Service Manual Download Page 61](http://html1.mh-extra.com/html/qualstar/tls-4000/tls-4000_technical-and-service-manual_3421438061.webp)
Value Type
Description
Accessible
TRUE/FALSE A TRUE value indicates that the drive has no cartridge inside and that it is
accessible.
Access.Valid
TRUE/FALSE A TRUE value indicates that the drive is communicating with the library.
However this does not verify that the drive ID is working. That can only be
done by setting ID’s and looking for the drives on the SCSI bus.
Barcodeable
Data
This value indicates whether or not the barcode reader can scan the barcode
label at the selected position. If the Barcodeable value is FALSE, the car-
tridge must be moved to another location before its barcode label can be
scanned.
Label
Data
This item is the barcode label data for the selected location, provided bar-
code information is available.
Label Error
TRUE/FALSE A TRUE value indicates that an error occurred while reading the barcode
label for the selected location.
Label Valid
TRUE/FALSE A TRUE value indicates that the Label and Label Error data for the selected
location are valid.
Occupied
TRUE/FALSE A TRUE value indicates that the selected location is occupied by a cartridge.
Occup.Valid
TRUE/FALSE A TRUE value means the Occupied status for the selected location is valid.
On My Side
TRUE/FALSE Not used on TLS-4xxx models.
Present
TRUE/FALSE A TRUE value indicates that a drive, holder, or other device is present at the
selected location.
Pres. Valid
TRUE/FALSE A TRUE value means the Present status for the selected location is valid.
Source Valid
TRUE/FALSE A TRUE value means the Source Location data for the selected location is
valid.
Source Loc.
Data
The Source value indicates the prior location of the cartridge that is currently
at the selected location. The Item value is an internal number. It is useful
only to a Qualstar Technical Support technician.
Synchronized
TRUE/FALSE When an inventory item is modified on one side of the library, the data is first
only in the corresponding sides Executive PCBA. The data will not be trans-
ferred to the opposite sides Executive PCBA until a synchronization occurs.
Type
Data
This value indicates the type of element that is at the selected location:
DRIVE, HANDLER, I/O PORT, or magazine SLOT.
Tape Ejected
Data
When the Type value is set to DRIVE, this value is displayed for the drive at
the selected location. The default value is FALSE. However, if the most re-
cent inventory scan found a tape ejected from the drive, this value will be
TRUE.
Table 5-3 Private\Display Locations Data
5-18
The Private Menu
501380 Rev. B