Upper Opening
CAROSL Cable
Lower Opening
Nylon Cable
Tie Pair (3)
Frame of TLS
Executive PCBA
Tie Wrap
Holes (6)
Figure 9-6 CAROSL Ribbon Cable Attached to TLS Frame
NOTE
Six Nylon Cable Ties will be needed to secure the CAROSL ribbon cable to the TLS frame.
5.
Thread the CAROSL cable through the upper opening in the TLS frame as
shown in Figure 9-6.
6.
Fold the CAROSL cable at a 45 degree angle so that the fold is centered between
the first two tie wrap holes and the remaining length of cable is centered be-
tween the remaining tie wrap holes as shown in Figure 9-6.
7.
At the uppermost set of tie wrap holes insert a Nylon Cable Tie through both
holes from the inside of the TLS.
8.
Position a second Nylon Cable Tie over the CAROSL cable, then attach it to both
ends of the first Nylon Cable Tie.
9.
Tighten the Nylon Cable Ties, without crimping the cable, until they secure the
CAROSL cable to the TLS frame.
10.
Repeat steps 7 through 9 for the two remaining sets of tie wrap holes. Make sure
that no slack is left in the CAROSL cable after the Nylon Cable Ties are in-
stalled.
9-6 TLS
Expansions
501380 Rev. B