5. Preflight check
Original Prusa SL1 kit assembly
81
STEP 19
Calibration 7
After you ensure, that everything is clean, place the tank back in its original position
and secure it with the screws.
Press "Continue"
STEP 20
Calibration 8
Check, whether the platform is properly secured on the printer. If not, tighten the
black knob.
Since the screw(s) in the cantilever isn't/aren't tightened, the eccentric might
wobble, but that is ok for now.
By gently pressing on the platform, ensure it is all the way down in the cantilever.
Press "Continue"
STEP 21
Calibration 9
Close the orange acrylic lid and continue with the next step.
Press "Continue"
STEP 22
Calibration 10
Open the lid and take a look inside the printer, make sure the edges of the platform
and the tank are parallel.
Press "Continue"
STEP 23
Calibration 11
Tighten firmly one or both screws on the cantilever to finish the adjustment.
Press "Continue"